5.4
Automatic switch-on for automatic operation
Only delivery, the switch-on automatic is set in such a way that operation with the most handpieces is
possible�
If the suction to a connected electrical appliance (e�g� a handpiece) does not react as required (e�g� does
not activate, even though a connected device is in operation) then the switch-on threshold for automatic
operation must be adjusted�
To change:
⇒ Switch suction on
Press for 3 sec�
♦ LED
and
♦ in the display a „0" blinks
⇒ Switch off electrical devices without standby mode�
⇒ Electrical device with a standby mode (e�g� handpieces), switch to standby mode (e�g� with a hand-
piece, switch only the control unit on without activating the handpiece)�
Press key
♦ in the display „1" blinks
⇒ An electrical device without standby mode must be switched on�
⇒ Operate the handpiece at the speed at which the suction is to be started and run for approx� 3 - 5 sec-
onds (so that overcurrent during start-up is not detected)�
Press key
♦ An acoustic signal acknowledges the information�
For devices with standby mode, these should be switched on approx. 5 minutes before setting to
avoid incorrect measurements.
5.5
"Change filter" - display
♦ Indicator LED (K) lights up, 3 beeps sound�
⇒ Change dust bag (see chap� 6�2)
or
⇒ Replace fine filter (see Chap. 6.3)
If the suction unit continues to be operated despite the "Change filter" display, it stops automati-
cally when the air flow falls below a fixed set value.
At the same time, the LED (K) flashes.
By switching OFF and ON, this detection is deleted and the suction starts again.
Operation with a clogged filter system may cause hazards and the suction unit may be damaged.
If the suction stops automatically when the filter is full, be sure to change the filter.
5.5.1
Adjust the sensitivity of the „Replace filter" indicator
It may be necessary to reduce responsivity if the suction support of the connected appliance has
a smaller diameter than the Silent TS. (<< 32.5 mm).
The „Replace filter" sensitivity can be adjusted within limits.
To do this:
• Switch the Silent TS off;
• Switch the Silent TS on, and in doing so keep the
blink� (5 = factory set parameter)
Press button,
- Reduce level of sensitivity,
- „Change filter" signal will appear later.
- ==> Dust bag will get very full
Press button,
- Increase level of sensitivity,
- „Change filter" signal appears more quickly.
- ==> Dust bag will get less full
Press button,
- Accoustic signal confirms successful adjustment.
blinken