TECHNICAL DATA
Working pressure 8 – 10 bar
Rated voltage
a)
Frequency
Capacity at 8 bar (FAD)
Working pressure
b)
Rated current
Motor power
Air tank volume
Air quality - filtration
Maximum operating pressure of safety valve
Noise level at 5 bar (L
Operating mode
PDP drying performance at 7 bar
Dryer low pressure alarm
Dryer high pressure alarm
Dryer high dew point alarm
Time to fill air tank from 0 to 7 bar
Dimensions (net)
w x d x h
c)
Net weight
Classification under EN 60601-1
a)
Specify the compressor version when ordering
b)
Consult any other range of pressure with the supplier
c)
Weight is indicative and only applies to the product without accessories
Applies to ambient temperatures of <30°C PDP – pressure dew point
d)
Dependence of compressor output on working pressure
03/2023
)
pA
d)
DK50 2x4VR/110/M
V, Hz
3x400V, 50Hz
l/min
380
8.0 – 10.0
bar
A
10.3
kW
2x2.2
l
110
m
-
bar
12.0
≤ 77.5
dB
%
S1-100
-40
°C
bar
< 3
˃11
bar
°C
˃ -40
s
120
mm
1085x675x1050
kg
186
27
NP-DK50 4VR 50, DK50 2x4VR 110-AD-5_03-2023
DK50 2x4VR/110S/M
3x400V, 50Hz
380
8.0 – 10.0
10.8
2x2.2
110
-
12.0
≤ 62.0
S1-100
-40
< 3
˃ 11
˃ -40
120
1260x830x1205
286
Class I.