Technical Data; Scope Of Delivery; Installation; General Installation Information - SPIDO TR 50 Mode D'emploi

Pompe de transfert pour gasoil et huies
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The liquid to be discharged must not contain any abrasive matters - such as sand, for
instance. If the pumped liquid actually does contain matters of this kind, the use of an intake
filter is indispensable. The fluid being discharged must not exceed the maximum temperature
indicated in the technical specification.
With storage containers from and above 1,000 litres the pump, by virtue of legal provisions,
must only be used if the fuel nozzle is equipped with an automatic stop feature (not included in
the scope of delivery).
3.

Technical Data

Model
Mains voltage / frequency
Nominal performance
Protection type
Suction port
Pressure port
1)
Max. flow rate (Q
)
max
Max. pressure
1)
Max. delivery height (H
)
max
Max. suction height
Max. size of the solids being pumped
Max. ambient temperature
Max. fluid temperature (T
max
Connection cable
Cable type
Weight (net)
Guaranteed sound power level (L
Measured sound power level (L
2)
Sound pressure level (L
)
pA
Dimensions (L x D x H)
Item no.
1)
The values were determined with free, unreduced in- an outlet.
2)
Noise emission values obtained according to the EN 12639 regulation. Measurement method according to
EN ISO 3744.
4.

Scope of delivery

The scope of delivery includes a suction hose, an intake filter with a check (or non-return) valve, a pistol-type fuel
nozzle (without automatic stop feature), connection pieces, hose clamps and sealing rings.
5.

Installation

5.1.

General installation information

When installing the unit, please make sure that the pump housing and the intake line are fully
vented, i.e. filled with the liquid being discharged. If this venting requirement is not observed,
the pump will not take in the liquid being discharged.
During the entire process of installation, the device must not be connected to the electrical
mains.
The pump is to be set up in a dry location, with the ambient temperature not to exceed 40°C.
The pump including the entire connection system has to be protected from frost and weather
influence.
9
)
2)
)
WA
2)
)
WA
230 V ~ 50 Hz
550 Watt
IP X4
30.93 mm
, female
(1 ")
30.93 mm
, female
(1 ")
2,100 l/h
3.5 bar
35 m
5 m
0 mm
40 °C
40 °C
1.5 m
H07RN-F
10.0 kg
68 dB
64.1 dB
56.1 dB
26 x 15 x 18 cm
2

Publicité

Table des Matières
loading

Table des Matières