When using the unit in a pond, please take the required action to ensure that no inhabitants of the pond will be
sucked in.
The pump is not suited to discharge saltwater, faeces, inflammable, etching, explosive or
other hazardous liquids. Please observe the max. temperature of the liquids to be discharged
stated in the technical data.
A distinctive feature of this pump is that it can briefly operated (max. 4 min.) with liquids with a
temperature up to 95°C (see Technical data)
Inside the pump, lubricants are used which may contaminate the liquids being discharged in
case of any improper operation or damage of the device. The lubricants used are biologically
degradable and non-hazardous to health.
3.
Technical Data
Model
Mains voltage / frequency
Nominal performance
Protection type
Pressure port
1)
Max. flow rate (Q
)
max
Max. pressure
1)
Max. delivery height (H
)
max
Max. submersion depth
Max. size of the solids being pumped
Max. fluid temperature (T
)
max
Max. short-term temp. of the pumped liquid (T
Max. cut-in frequency in one hour
Length of connection cable
Cable type
Weight (net)
2)
Min. self-priming level (A)
2)
Min. suction level (B)
2)
Cut-in level (C)
2)
Cut-out level (D)
Dimensions (L x D x H)
1)
The values were determined with free, unreduced outlet.
2)
The values between brackets refer to the illustrations given at the end of these operating instructions.
3)
If the water temperature is between 50°C and 95°C the device will only work for 4 minutes and then will switch off
automatically to allow the motor to completely cool.
4.
Scope of delivery
The scope of the delivery of this product includes:
One pump with connection cable, two connection ports, one reducing part, one operating manual. Please verify
that the scope of delivery is complete. Depending on the purpose of the application, additional accessories may
be necessary (please refer to the chapters titled "Installation" and "How to order spare parts").
If possible, keep the packing until the warranty period has expired. Please dispose of the packing materials in an
environmental-friendly manner.
5.
Installation
5.1.
General installation information
During the entire process of installation, the device must not be connected to the electrical
mains.
8
ECC PRO 400
230 V ~ 50 Hz
1,500 Watt
IP 68
57,29 mm (2 "), female
24,000 l/h
1.1 bar
11 m
7 m
40 mm
50 °C
3)
<4 min)
95°C (max. 4 min.)
max.
30, evenly distributed
10 m
H07RN-F
~ 13.8 kg
115 mm
55 mm
440 mm
130 mm
24,5 x 17 x 42,5 cm
2