Télécharger Imprimer la page

Trix Minitrix 212 / V 100 Serie Mode D'emploi page 11

Publicité

Important: Changes in the settings market with ( * ) for the
Selectrix mode of operation automatically lead to changes in
the DCC mode of operation and versa!
CV
Discription
1
*
address
3
acceleration delay
4
braking delay
5
*
maximum speed
17
extendet address (upper part)
18
extendet address (lower part)
29
bit 0: Travel direction polarity reversal
bit 1: number of speed levels 14/28
bit 2: DCC Operation with braking Block
DCC-, Selectrix and DC power operation
bit 5: address size 7 bit / 14 bit
49
*
pulse width for motor control
50
*
ule variant
51
*
bit 0: motor polarity reversal
bit 1: lighting polarity reversal
bit 2: track polarity reversal
*** The values for the desired settings must be added.
All manuals and user guides at all-guides.com
DCC Value
1 - 127
0 - 127
0 - 127
1 - 7
CV 29, bit 5=1
CV 29, bit 5=1
Value
0 / 1
***
0 / 2
0. 1, 2, 3, 4, 5, 6,
0 / 4
7, 32, 34, 35, 36,
37, 38, 39
0 / 32
0 - 3
0 - 3
0 / 1
0 - 7
0 / 2
0 / 4
Selectrix Value
1 - 99
1 - 7
1 - 7
1 - 7
not necessary
not necessary
not
necessary
1 - 4
1 - 4
not necessary
11