Using the toilet
4.13 Troubleshooting
Fault
Flushing no longer functions
Cassette leaking
No filling level display
All manuals and user guides at all-guides.com
Possible cause
Fuse defective
Seal worn
Float in the cassette has got stuck
or is jammed by toilet paper
18
Action you can take
Replace fuse
(see chpt. 4.8)
Check electrical terminals and con-
nections in the case of repeated fai-
lure.
Replace seal on the blade
(see chpt. 4.2.1)
Clean float in the cassette
(do not use any high-pressure
cleaner)