H
ow do you install your oven?
Electrical
connection
Operating voltage ..................................................... 220-240 V ~ 50-60 Hz
Total oven power .......................................................................... 1.77 kW
Energy consumption
- heating up to and holding at 100°C for one hour ......................... 0.71 kWh
Useful dimensions of your oven
Width .......................................................................................... 38.5 cm
Height ......................................................................................... 18.2 cm
Depth .......................................................................................... 33.5 cm
Net capacity ............................................................................. 23.5 litres
24/09/2004
13:32
All manuals and user guides at all-guides.com
For permanent installation, be mindful to add a
standardised, compliant cut-off device in the
electrical conduit. Otherwise the appliance must
be positioned so that the electrical outlet is
accessible after the unit has been built-in.
You must use an electrical receptacle that
contains a ground wire and is connected in
compliance with applicable safety standards.
Your electrical installation must be equipped with
10-ampere thermal-sensitive protection.
Do not operate the oven if the power cable or its
plug are damaged. In this case, they must be
replaced by the manufacturer, its After Sales
Service department of a person of similar
qualifications so as to avoid any danger.