12.2. Connecting the cabinet pressure gauge to the compressor
Remove the plug (1) from the threads (2) on the
pneumatic block of the compressor.
Connect the cabinet pressure gauge hose to the
threaded fitting.
Fig. 7: Connecting the cabinet pressure gauge to the compressor
12.3. Connecting the condensate vessel
Connect the condensate drain hose to the condensate bottle on compressors in cabinet.
(Fig. 8)
Put the plug in free inlet of the condensate collection vessel.
Route the hose through the opening in the rear wall of the cabinet for compressors with
dryers. Connect the condensate collection tank using the hose to the condensate outlet on
the dryer.
Injury hazard.
Do not connect the condensate drain directly to a waste drain! Passers-by may
be injured!
Fig. 8:Connection of condensate collection vessel
NP-DK50 2V-4_12-2022-AD
28
INSTALLATION
12/2022