monoMIG 200ik
OPERATION
3.1 User Interface
5
6
7
Used to set the wire speed and voltage values for the desired welding.
Adjustment Pots
1-2
Shows the numerical value of the selected welding parameter, current and voltage value during
Digital Panel
welding, idle wire speed and idle set voltage.
3-4
To set the welding parameter times,
Sub Menu
Pre 0.0/10.0 s Pre-Gas Duration
Pos 0.0/10.0 s Final Gas Duration
Tof 0.2/20.0 s Spot Welding Passive Duration Crt On/Off Used to put the crater in active or passive
5
Used to increase and decrease the duration in the selected menu.
Sub Menu Adjustment Buttons
6-7
Selects the gas to be used in the welding operation.
Gas Mode Selection Button
When Ar gas is selected led 9, when Mixed gas is selected led 10, when CO2 gas is selected led 11 lights.
8
For the wire with 1.0 thickness led 13, for the wire with 0.8 thickness led 14, for the wire with 0.6
Wire Thickness Selection Button
thickness led 15 lights.
12
Used to select one of the modes: position 2, position 4 or spot welding.
Trigger Mode Selection Button
When position 2 is selected led 19, when position 4 is selected led 18, when spot welding is selected
led 17 lights.
16
www.magmaweld.com
3
4
11
1
10
9
2
8
Brn 0.0/100 ms Burnback Duration
Ton 0.2/20.0 s Spot Welding Active Duration
position.
Operation
17
15
19
14
18
13
17
12
16
USER MANUAL