Les langues disponibles

en-us Electrical connection
Remove the top nut (has an attached locking washer)
3.
from each post.
Note: DO NOT remove the second nut/washer on each
post; these must stay in place to anchor the internal
wiring attached to the terminal block.
Remove the green grounding screw
4.
end of the grounding strap.
Remove the grounding strap from the center post of the
5.
terminal block.
Rotate the grounding strip
6.
and align the hole with the grounding hole below the ter-
minal block.
Use the green grounding screw
7.
wire
on top of the grounding strap.
Tighten the grounding screw firmly, but do not over-
8.
tighten.
12
from the lower
so that the wide end is up
to attach the green
Attach the red wire to the left terminal using one of the
9.
nut/washers removed previously.
r
Red
w
White
g
Green
b
Black
Attach the white wire to the center terminal using one of
10.
the nut/washer parts.
Attach the black wire to the right junction block terminal
11.
using one of the nut/washer parts.
Tighten all connections securely and replace terminal
12.
block cover.
Properly secure strain relief.
13.
→  "Routing the electrical cord", Page 11
Note: DO NOT plug in the range at this time.
Installing a three-wire connection
Alternate method
Note: The four-wire connection (above) is preferred, but
where local codes and ordinances permit grounding
through the neutral and where conversion to four-wire is
impractical, the unit may be connected to the power sup-
ply via a three-wire connection.
Disconnect electrical power at breaker box.
1.
Remove the terminal block cover to expose the terminal
2.
block.