"FILTER"
or
"CUT/OUT"
message
appears
on
the
capacitive touch panel
Board error code
E14 or E24 or E34 message
appears on the capacitive
touch panel display.
1, 2 e 3 are respectively the
left, centre and right bowls.
E15 or E25 or E35 message
appears on the capacitive
touch panel display.
1, 2 e 3 are respectively the
left, centre and right bowls.
E11 or E21 or E31 message
appears on the capacitive
touch panel display.
1, 2 e 3 are respectively the
left, centre and right bowls.
E12 or E22 or E32 message
appears on the capacitive
touch panel display.
1, 2 e 3 are respectively the
left, centre and right bowls.
E01 or E04 or E05 or E06
message
appears
on
the
capacitive
touch
panel
display.
E02 message appears on the
capacitive
touch
panel
display.
E03 message appears on the
capacitive
touch
panel
display.
Edition: June, 2013
All manuals and user guides at all-guides.com
•
The filter is dirty and needs to be
cleaned
•
The unit is positioned too close to a wall
or other object restricting air flow and
causing the machine to run at a higher
temperature
•
The filter is not properly installed
•
The unit has been installed near a heat
source, such as a coffee machine, ice
maker or cold beverage machine which
expels hot air from its vents, causing the
machine to run at a high temperature.
Possible cause
•
The product consistency is too high
•
An ice block is obstructing the auger
rotation
•
An ice block is blocking the auger
rotation
•
The gear motor is defective
•
The
temperature
probe
corresponding bowl is short circuited.
•
The
temperature
probe
corresponding bowl is disconnected.
•
The control board is defective
•
The condenser temperature probe is
short circuited.
•
The condenser temperature probe is
disconnected.
Revision: 7
•
Clean and replace filter following
instructions
•
Reposition unit to maximize
ventilation space (see
installation figures)
•
Properly install filter see
•
Reposition unit to maximize
ventilation space (see
installation figures)
Solution
•
Reduce the product consistency
•
Remove ice blocks
•
Remove ice blocks
•
Replace the gear motor
•
of
the
Check and replace the probe
•
of
the
Check and connect the probe
•
Replace the board
•
Check and replace the condenser
probe
•
Check
and
condenser probe
Pag. : 48/76
connect
the