"FILTER"
or
"CUT/OUT"
message
appears
on
the
capacitive touch panel
Board error code
E14 or E24 or E34 message
appears on the capacitive
touch panel display.
1, 2 e 3 are respectively the
left, centre and right bowls.
E15 or E25 or E35 message
appears on the capacitive
touch panel display.
1, 2 e 3 are respectively the
left, centre and right bowls.
E11 or E21 or E31 message
appears on the capacitive
touch panel display.
1, 2 e 3 are respectively the
left, centre and right bowls.
E12 or E22 or E32 message
appears on the capacitive
touch panel display.
1, 2 e 3 are respectively the
left, centre and right bowls.
E01 or E04 or E05 or E06
message
appears
on
the
capacitive
touch
panel
display.
E02 message appears on the
capacitive
touch
panel
display.
E03 message appears on the
capacitive
touch
panel
display.
Edition: June, 2013
All manuals and user guides at all-guides.com
The filter is dirty and needs to be
cleaned
The unit is positioned too close to a wall
or other object restricting air flow and
causing the machine to run at a higher
temperature
The filter is not properly installed
The unit has been installed near a heat
source, such as a coffee machine, ice
maker or cold beverage machine which
expels hot air from its vents, causing the
machine to run at a high temperature.
Possible cause
The product consistency is too high
An ice block is obstructing the auger
rotation
An ice block is blocking the auger
rotation
The gear motor is defective
The
temperature
probe
corresponding bowl is short circuited.
The
temperature
probe
corresponding bowl is disconnected.
The control board is defective
The condenser temperature probe is
short circuited.
The condenser temperature probe is
disconnected.
Revision: 7
Clean and replace filter following
instructions
Reposition unit to maximize
ventilation space (see
installation figures)
Properly install filter see
Reposition unit to maximize
ventilation space (see
installation figures)
Solution
Reduce the product consistency
Remove ice blocks
Remove ice blocks
Replace the gear motor
of
the
Check and replace the probe
of
the
Check and connect the probe
Replace the board
Check and replace the condenser
probe
Check
and
condenser probe
Pag. : 48/76