Télécharger Imprimer la page

Napoleon Acies Serie Manuel D'installation page 44

Masquer les pouces Voir aussi pour Acies Serie:

Publicité

Les langues disponibles

Les langues disponibles

finish framing - after appliance installation
EN
see-thru flush
note:
Shaded components (finish framing) must be
non-combustible materials.
Finish framing must be built after the appliance has
been placed in its final position and venting
connected.
minimum framing
Ref
39 15/16" (101.4cm)
K
16 3/16" (41.1cm)
E
F
53 13/16" (136.7cm)
J
Optional - Appliance does not need to be elevated above floor
L
44
W415-1707 / B / 06.04.18
All manuals and user guides at all-guides.com
Drywall
Insulation
L38
73" (185.4cm)
Ceiling
K
E
F
L50
39 15/16" (101.4cm)
16 3/16" (41.1cm)
65 13/16" (167.2cm)
73" (185.4cm)
L
J
note:
The L series requires a minimum en-
closure height of 73" measured from
the bottom of the appliance. For tem-
perature requirements, this area must
be left unobstructed. Some venting
configurations that require more verti-
cal rise will require a larger enclosure
to provide minimum vertical clearance
between vent pipes and combus-
tibles. It is also recommended that the
enclosure be ventilated at the top and
bottom to circulate the hot air.

Publicité

loading