Before framing your appliance, determine vent requirements before deciding the final location of the appliance.
After rough framing, place the appliance in its final position.
single-sided
J
minimum framing
Ref
E
F
J
*L
see-thru
minimum framing
Ref
E
16 3/16" (41.1cm)
53 13/16" (136.7cm)
F
J
Optional - Appliance does not need to be elevated above floor
*L
73" (185.4cm)
All manuals and user guides at all-guides.com
rough framing - before appliance installation
L
E
F
L38
17 15/16" (45.6cm)
53 13/16" (136.7cm)
Optional - Appliance does not need to be elevated above floor
73" (185.4cm)
L
E
F
J
L38
note:
Before framing the appliance, ensure to install the
firestop first.
note:
The L series requires a minimum en-
closure height of 73" measured from
the bottom of the appliance. For tem-
perature requirements, this area must
be left unobstructed. Some venting
configurations that require more verti-
cal rise will require a larger enclosure
to provide minimum vertical clearance
between vent pipes and combus-
tibles. It is also recommended that the
enclosure be ventilated at the top and
bottom to circulate the hot air.
L50
17 15/16" (45.6cm)
65 13/16" (167.2cm)
73" (185.4cm)
note:
Before framing the appliance, ensure to install the
firestop first as it will not fit between the studs if
installed after framing.
note:
The L series requires a minimum en-
closure height of 73" measured from
the bottom of the appliance. For tem-
perature requirements, this area must
be left unobstructed. Some venting
configurations that require more verti-
cal rise will require a larger enclosure
to provide minimum vertical clearance
between vent pipes and combus-
tibles. It is also recommended that the
enclosure be ventilated at the top and
bottom to circulate the hot air.
L50
16 3/16" (41.1cm)
65 13/16" (167.2cm)
73" (185.4cm)
* Minimum enclosure
height maybe higher de-
pending on venting con-
figuration (see minimum
distance to combustibles).
W415-1707 / B / 06.04.18
EN
27