Télécharger Imprimer la page

Napoleon Acies Serie Manuel D'installation page 24

Masquer les pouces Voir aussi pour Acies Serie:

Publicité

Les langues disponibles

Les langues disponibles

rough framing - before appliance installation
EN
4.1
minimum framing dimensions
6" (15.2cm) min.
*E
*Single-sided model illustrated.
Horizontal vent sections: A minimum clearance of 3" (76mm) on the top outside of the enclosure and 2" (51mm)
on the sides and bottom outside of the enclosure all around the vent pipe on all horizontal runs to combustibles is
required. Horizontal vent sections within enclosures require a minimum clearance of 6"(152mm) at the top of the
vent pipe.
Vertical vent sections: A minimum of 1" (25mm) all around the vent pipe on all vertical runs to combustibles is
required except for clearances in appliances enclosures. Vertical vent sections within enclosures require a minimum
clearance of 1" (25mm) around the vent pipe.
24
W415-1707 / B / 06.04.18
All manuals and user guides at all-guides.com
F
Do not put objects in front of the
appliance (minimum distance of 4 feet)
minimum framing
L38
17 15/16" (45.6cm)
*E
53 13/16" (136.7cm) 65 13/16" (167.2cm)
F
G
63 3/4" (162cm)
18 3/16" (46.2cm)
H
90 3/16" (229cm)
I
H
F
I
L50
17 15/16" (45.6cm)
72 1/4" (183.5cm)
18 3/16" (46.2cm)
102 3/16" (259.5cm)
G
1" (2.54cm) min.

Publicité

loading