PROBLEM
After making the various connections and supplying voltage, all leds are OFF.
The photocells are not lit and the motor does not rotate
The gate opens, but does not close after the set time
The gate does not open and does not close when pressing the various OPEN-
CLOSE-START-RADIO buttons.
When the gate is open, pressing the START, RADIO button or the CLOSE button,
the gate does not move.
the gate triggers an alarm due to over-current, signalled by 3 buzzer tones.
LED DL1 flashes ON/OFF 250ms.
When programming the time, the gate stops and the buzzer emits a tone for 10
s, with pause for 2 s.
Impact sensor intervenes during the movement
The buzzer emits 2 long tones and the gate does not move
The remote control does not work. Led DL12 lit red
After verifying the correct functioning of the operator, fix the control panel cover and secure the cover of the operator using the screws and bolts provided. The fixing bolt of the operator's cover
must be tighten into the nuts previously inserted in the aluminum base.
Check the integrity of fuse F1.
In case of faulty fuse, replace it only with one of the same value: F1 = T 1,6A
Check the integrity of fuse F2.
In case of faulty fuse, replace it only with one of the same value: F2 = T 10A
Check that led DL11 turns on. If it is OFF, turn the trimmer clockwise.
Or, check that the photocells are not engaged.
It is also possible that you have pressed the STOP button with the gate open, temporarily blocking the automatic
closure.
Edge contact or photocell fault with DIP 4 to OFF. Adjust or replace its contact.
Or, check that manual release device is not open.
Clock function enabled. Check the status of the B.I.O. input.
Or, photocells auto-test failed = > check the connections between the electronic panel and photocells.
Check the sliding of the gate, making sure that there is no friction. Only if necessary, set DIP 7 to OFF to exclude
the impact sensor.
DIP 1 set to ON. Set it to OFF.
Or, an edge or photocell is broken. The movement is allowed only by hold-to-run command.
Incorrect programming sequence. Set DIP 2 to OFF.
Bring the gate at about 20 cm from the end closure and repeat the programming sequence.
Turn the SENS trimmer clockwise
Safety edge with 8,2 KΩ resistor. Remove the resistor or configure the EDGE input via the RIBGATE app
Lack of radio module in connector J6 or faulty radio module.