Télécharger Imprimer la page

RIB K400 L1 24V-CRX Mode D'emploi page 32

Publicité

Les langues disponibles
  • FR

Les langues disponibles

G
POINT A -
ELECTRIC CONNECTIONS
B
J19
J2
J3
J4
J5
Power supply 230 Vac 50/60 Hz - external to the control panel
J1
N F
- (120 V 60 Hz upon request)
A+COM
+ 24Vdc accessories power supply
J2
A-
- 24Vdc accessories power supply
A+TEST
+ 24Vdc Photocells self-test power supply
OPEN
Open pulse contact (NO)
CLOSE
Close pulse contact (NO)
START
Single pulse contact (NO)
J3
PED.
Pedestrian opening pulse contact (NO)
B.I.O.
Clock contact (NO)
COM A+
Contacts common / Positive 24 Vdc
COM A+
Contacts common / Positive 24 Vdc
STOP
Stop pulse contact (nc)
PHOT 1
Photocells 1 contact (nc)
J4
PHOT 2
Photocells 2 contact (nc)
EDGE 1
Edge 1 contact (nc)
EDGE 2
Edge 2 contact (nc)
J5
Radio Antenna 433MHz
J6
RADIO
Connector for radio module ACG8069
BATTERY CHARGER
J7
Connector for battery charger board (code ACG4776 optional)
(24V DC SOLAR)
J8
BATTERY +/-
Battery connectors (optional)
B – SETTINGS
DIP 1
adjust stroke in line with electrical or magnetic limit switches (point C)
DIP 2
programme full opening (point D)
DIP 2-1
programme pedestrian opening times (point E)
DIP 1-2
save/delete radio codes for full opening control (point F)
DIP 1-3
save/delete radio codes for pedestrian opening control (point G)
DIP 1-2-3
save/delete radio codes for relay R-AUX command (point H)
DIP SWITCHES CONTROL
DIP 4
Photocells always active (OFF) - Photocells active only during closing (ON)
DIP 5
Pre-blinking (ON) - Normal blinking (OFF)
DIP 6
Single pulse command (START) and RADIO - step-by-step (ON) - automatic (OFF)
DIP 7
Photocells AUTO-TEST activation (ON-activated).
DIP 8
Available
DIP 9
Available
DIP 10
Gradual brake (ON-activated)
DIP 11
Gradual start (ON - activated)
DIP 12
Activate the radio system SUN (ON) - SUN PRO (OFF)
DIP 13
Heater (ON - activated)
J15
J17
J16
J13 J12
J6
J7
J8
J9
J10
J11
J12
J13
J14
J15
J16
J17
J18
J19
F1
F2
DIP 14
DIP 15
OFF
ADJUSTMENTS
RUN TRIMMER - high-speed regulator
With this trimmer it is possible to adjust the motor speed (set as standard to the max speed).
The adjustment is quite useful to align the automation with the European standards on impacts.
LOW SP TRIMMER - slow speed approach regulator
The slow speed control is performed by adjusting the LOW SP trimmer which changes the
voltage output across the motor(s) (turning it clockwise increases the speed).
Adjustment is performed to determine the correct speed at the end of opening and closing
according to the gate or when there is friction that might cause the system to function poorly.
TCA TRIMMER - AUTOMATIC CLOSING pause time regulator for TOTAL or PEDESTRIAN openings
32
J14
PROG
J1
J11
F
N
F2
F1
J9
10VAC
Connectors for secondary 10 Vac transformer
24VAC
Connectors for secondary 24 Vac transformer
SERIAL COM / SYNC
Connector for serial connection
SECURITY LOCK
Connector for manual release switch
LIMIT SWITCH
Connector for electrical or magnetic limit switches
MOTOR
Connector for 24 Vdc motor and 5 Vdc encoder
X K800
Connectors for motor K800 connection (do not use)
APP
Connector for APP Card
APP+
Connector for APP+ Card
RS485 termination of J17
R-AUX
Auxiliary relay contact (NO) Max 700 W
SIGNAL -
Open gate indicator 24 Vdc max 3 W
COM A+
Contacts common / Positive 24 Vdc
Negative flasher 24 Vdc 20 W (code ACG7072)
SENS
Trimmer for adjusting sensitivity to impact against an obstacle
Trimmer for automatic closing time adjustment (DISABLED BY
TCA
FACTORY AND DL11 LED OFF)
RUN
Trimmer for high speed adjustment operations
LOW SP
Trimmer for low speed adjustment operations
PROG
Programming key
T 1,6 A
Transformer protection fuse (external to the card L1 24V)
T 10 A
Motor protection fuse
Available
DIP 16
OFF
K400
F
> PHASE
N
> NEUTRAL
> EARTH

Publicité

loading

Ce manuel est également adapté pour:

Aa40928Aa40929