W 500
Problem
Width of paint
spray cannot be
adjusted
Device does not
function
Paint in the
ventilating hose
Poor covering
capacity on the
wall
24. Technical Data
Max. viscosity:
Power source:
Power consumption:
Atomizing output:
Max. delivery rate
Double insulation:
Sound pressure level*:
Sound pressure output*
Oscillation level:
Air hose length:
Weight:
* Measured in accordance with EN 60745-1
Information about the oscillation level
The specified oscillation level has been measured according to a standard test
procedure and can be used to compare against electric tools.
The oscillation level is also for determining an initial assessment of the vibrational strain.
Attention! The vibration emission value can differ from the specified value when the
Cause
•
Adjustment ring is not connected
to the peg on the air cap
•
Air screen is clogged up
•
Device overheated
•
Diaphragm soiled
•
Diaphragm defective
•
Spray material is too cold
•
Highly absorbent surface
or paint with poor covering
capacity
•
Distance too large
Technical Data
3300 mPas
230 V
, 50 Hz
~
370 W
120 W
375 ml/min
80 dB (A); Uncertainty K = 4 dB
93 dB (A); Uncertainty K = 4 dB
< 2.5 m/s²; Uncertainty K = 1.5 m/s²
3.5 m
approx. 3.1 kg
Remedy
➞ Connect adjustment ring and
peg
➞ Disassemble and clean
➞ Unplug the power plug, let
the device cool down approx.
30 minutes, do not bend the
hose, check the air filter, do
not cover the intake slots
➞ Clean the diaphragm
➞ Replace the diaphragm
➞ The material you are spraying
should be at room temperature
➞ Cross spray (Fig. 10)
➞ Closer to the object
GB
31