1. Drain bolt
1. Boulon de vidange
1. Tapón de vaciado
4. Remove the oil filler bolt and the drain bolt to
drain the oil.
5. Install the drain bolt and tighten it to the spec-
ified torque.
Tightening torque:
Drain bolt (final gear case):
23 Nm (2.3 m·kgf)
6. Fill the final gear case with oil.
Recommended oil:
See page 10-3.
Oil quantity:
Periodic oil change:
0.25 L
Total amount:
0.27 L
CAUTION:
_
Be sure no foreign material enters the final
gear case.
_
8-25