Model Identification - Pulsafeeder Eclipse Série Instructions D'installation Et De Fonctionnement

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

13. Model Identification

Position
1
2 and 3
4
5
6
7
8
9
In the above example, the Eclipse pump E02ELVF-X is a Model 2 pump, ETFE base materials, FNPT process connections,
carbon bearings, FKM O-rings, and a NEMA 56 motor mounting.
Options Description:
Complete pump model number with no magnet options ("X" or "A" in position 9) includes drive magnet and all necessary
motor mounting hardware for a specified motor size.
Option "Y" in position 7 is for a bare pump with drive magnet, but no motor mounting hardware (magnet hub, motor adapter
when applicable). This will typically be used as a spare pump or as inventory until a specific motor size is identified.
Option "N" in position 9 is for a bare pump without drive magnet. This will typically only be used as a "wet end" repair kit
for an existing unit when the drive magnet is not required with the new pump. This option can only be used in combination
with a "Y" code in position 7.
Consult factory for availability of option combinations not covered in the above chart.
Sample
E
02
Base Material
E
and Connections
L
V
F
-
X
53
Specifies
E - Eclipse
Size
02
05
12
25
75
E - ETFE, FNPT
B - ETFE,
F - ETFE,Flange
P - Polypropylene, Flange
Bearings
L – Carbon Graphite
B - Silicon-Carbide
O-rings
V – FKM "A"
E - EPDM
Motor
F - NEMA 56C
Mounting
O - NEMA 143TC-182C
R - NEMA 182-184TC
H - IEC B14 63
K - IEC B14 80
P - IEC B14 100/112
Y - No motor mount kit
position 8 is a dash
Options
X – Complete Pump (No Options)
A – Bearing Flush Ports
N – Pump Wet End Only
B – Options A and N
Options
ISO 7-1

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Eclipse 2Eclipse 5Eclipse 12Eclipse 25Eclipse 75

Table des Matières