Equipment
Equipment in Group II, Category 2, is intended for use in areas in which explosive atmospheres caused by gases,
vapors, mists or air/dust mixtures are likely to occur.
G & D Atmospheres
In G type Explosive atmosphere (Gas, vapor, mist) equipment is suitable for use in Zone 1 areas.
In D type Explosive atmosphere (Dust) equipment is suitable for use in Zone 21 areas.

Temperature Class

Temperature class TX based on ambient and pumped fluid temperature.
Different temperature classes can be achieved based on fluid and ambient temperatures (See chart)
Temperature Class and Maximum Liquid Temperatures
Maximum Surface
Temperature
Temperature C
Class
Permitted
T1
T2
T3
T4
T5
T6
* Maximum Temperature Class for Eclipse Series Pumps is T6.
Technical Support & Service
For technical support or service contact:
Pulsafeeder Inc.
2883 Brighton Henrietta Townline Road
Rochester, New York
14623
USA
(585) 292-8000
Max. Liquid or Ambient Temperature C
(Dust)
Sealed Pumps
450
260
300
225
200
145
135
90
100
65
85
50
Magnetic Drive
230
225
145
90
65
50
Protective Earth Ground Symbol