INSTRUCTIONS FOR USE
CC 10
10
9
8
7
6
TEMP
5
4
3
2
TIME
1
1
2
3
Functions.
1 = setting scale. 2 = time settings. 3 = temperature settings. 4 = on. 5 = off.
Temperature setting.
(The heater must be switched on)
Press TEMP – the previous temperature setting is displayed.
The numbers indicate a rising temperature scale. Experiment to find the temperature
that suits you best. Begin for example by turning the thermostat dial to position 4. If
you later find that you would prefer a higher or lower temperature, adjust the dial up or
down until you find the ideal bathing temperature for you (usually 70-90°C (158-
194°F) for traditional dry and wet sauna baths, 40-45°C (104-113°F) for steam
saunas and herb saunas).
Manual on/off.
Press ON to switch the facility on. Press OFF to switch it off. (the LED goes out).
A memory function automatically sets the previous temperature.
Press TEMP – to change the pre-set temperature.
The built-in timer automatically switches the sauna heater/steam generator off after
3 hours. If you want to switch it off earlier than that, press OFF. To extend the sauna
time, press ON.
Timer settings.
(The heater must be switched off)
The numbers in this case represent the timer times (= the number of hours until the
heater automatically switches on). To set the timer:
Press TIME – use the arrow keys to select the desired pre-set time, 1–10 hours.
Press ON – the timer is activated and the time indicator blinks during the pre-set
time period. Once the heater switches itself on, it remains on for 3 hours, after which
it automatically switches itself off. If you want to switch it off earlier than that, just
press OFF. To extend your sauna time, press ON.
Main power switch.
To be changed more than once: At the bottom of the relay box, the SE unit and the
smaller types of steam generators is a main power switch that disconnects the heater
entirely from the electrical supply. This main switch should only be used if the sauna
will not be used for a longer period, such as several weeks. To be changed more than
once: The memory function must be reset each time the power is interrupted.
INSTRUCTIONS FOR USE
CC 50
LIGHT
ON/
OFF
1
2
3
Functions.
1 = lighting. 2 = on/off. 3 = temperature setting. 4 = time setting. 5 = reduce
temperature/time. 6 = increase temperature/time. 7 = display.
Lighting.
Lights automatically when the facility starts and switches off automatically when the
facility shuts down. You can also switch the lighting on or off manually by pressing
LIGHT.
All manuals and user guides at all-guides.com
5
OFF
4
ON
00
TEMP
6
TIME
4
Main power switch.
To be changed more than once: At the bottom of the relay box, the SE unit and the
smaller types of steam generators is a main power switch that disconnects the heater
entirely from the electrical supply. This main switch should only be used if the sauna
will not be used for a longer period, such as several weeks. To be changed more than
once: The memory function must be reset each time the power is interrupted.
The thermometer in the sauna/steam bath should be placed at such a height that the
temperature corresponds exactly to the numbers in the panel of the CC 50.
SETTINGS
CC 50, all models
Setting the bathing temperature.
Press TEMP – the previous temperature is displayed. Use the up and down arrows
(
) to change the temperature.
Manual on/off.
Press ON to switch the facility on. Press OFF to switch it off. (the LED goes out). If
you forget to switch off the generator manually, it switches off automatically after 3 or
12 hours - depending on the type of control panel.
Timer settings.
(The sauna must be switched off)
Press TIME (the hour digits blink) – set the number of hours until you want to use
the sauna using the up and down arrows (
Press TIME (the minute digits blink) – set the number of minutes until you want to
use the sauna using the up and down arrows (
(Important: The hour or minute digits must be blinking before you press ON).
Press ON – the on time is activated and a red LED blinks until the sauna
automatically starts after the pre-set time. The heater switches off automatically after
3 or 12 hours – depending on the type of control panel.
You can switch off the sauna manually at any time by pressing OFF.
Code lock to prevent settings from being changed.
First program as above, then wait at least 20 seconds. Press on the down arrow ( ),
hold it down and press TEMP and TIME at the same time. The code lock, which
prevents all changing of settings, is now activated. To return to unlocked mode, press
the down arrow ( ), hold it down and press OFF at the same time.
Code lock that only prevents changing of the temperature
setting.
First program the temperature as above, then wait at least 20 seconds. Press TIME,
hold it down and press TEMP and LIGHT at the same time. The code lock, which
prevents changing of the temperature settings, is now activated. To return to
unlocked mode, press the down arrow ( ), hold it down and press OFF at the same
time.
INSTRUCTIONS FOR USE
CC 100
12
M o n d a y 1 0 : 0 0 : 0 0
C C 1 0 0 i s o f f
P r e s s O N t o s t a r t
P r e s s I N F O f o r h e l p
TEMP
ON
OFF
1
2
3
Functions.
1 = on, 2 = temperature settings, 3 = off, 4 = lighting, 5 = move left, 6 = reduce
temperature/time and move down, 7 = move right, 8 = increase temperature/time
and move up, 9 = settings menu, 10 = information menu, 11 = display.
12 = built-in, factory-set processor, can be customised as desired.
A simplified version of these instructions are found under INFO in CC 100.
CC 100 has a built-in power reserve and you can choose between 7 different
languages.
After each power failure, the model designation of the control panel is
displayed for five seconds.
).
).
11
10
9
INFO
MENU
LIGHT
6
5
4
5