5.3
TURNING THE CHARGER ON AND OFF
The CPS2 OEM 24V/60A charger starts operating as soon as it is switched on (input power cable connected and powered).
The CPS2 OEM 24V/60A charger stops operating when it is no longer powered up (input power cable disconnected or the
installation's circuit-breaker in the OFF position).
ATTENTION: if the charger On/Off option is used, the charger may not be in operation while still being powered up
(dangerous voltage).
6
EQUIPMENT MAINTENANCE AND REPAIRS
6.1
OVERVIEW
This paragraph deals with equipment maintenance and repairs. Proper operation of the product and its service life are
dependent on strict compliance with the following recommendations.
6.2
EQUIPMENT MAINTENANCE
Disconnect the battery charger from the AC network before starting any maintenance work.
If appliances are in a dusty atmosphere, vacuum-clean them regularly, since dust deposits may adversely affect heat release.
Check the state of battery charge every 3 months.
The tightness of nuts and screws should be checked annually to ensure efficient operation of the appliance (particularly in
hostile conditions: vibrations, shocks, high variations in temperature etc.).
A full technical inspection by a Cristec-accredited engineer is recommended every five years. This can also be done at our
plant.
6.3
EQUIPMENT REPAIR
Disconnect the battery charger from the AC power network and disconnect the batteries before undertaking any repairs.
When fuses have blown, only use fuses of the type and size recommended in this manual.
Please contact a reseller or Cristec for any other repairs.
7
SAFETY PRECAUTIONS
7.1
REFERENCE STANDARDS
Class I equipment compliant with standard NF EN 60950
Installation instructions are set out in standard NFC 15-100 and the specific ISO13297 standard entitled "pleasure boats –
electrical systems – Installing distributed AC current".
7.2
PERSONAL SAFETY PRECAUTIONS
Only an electrician or professional installer should install the appliance.
The incoming AC power network should be cut off before working on the equipment.
7.3
PRECAUTIONS REGARDING THE RISK OF FIRE AND EXPLOSIONS
Only use the fuses listed herein.
Near batteries : keep the room well-ventilated, do not smoke, never use bare flames.
CPS2OEM24V-60ADEA.DOC
22