Operation
4.2.6
Starting up
•
Slide the ON-OFF switch
•
The battery charge level
•
The battery
charge level that is too low can result in serious injury and damage due to sudden dropping of
the lifted load!!!
•
The battery can be charged at any time without reducing the battery life.
•
If the holding force begins to decrease noticeably even though the battery is fully charged, check
the rubber foam seal for wear or damage. Do not attempt to lift a load with the unit until the rubber
foam seal has been replaced.
•
Position the device on the surface to be lifted.
•
To switch on the vacuum pump and trigger suction of the load, press the green button
the device at the handle for a few seconds with light force against the load to be lifted and the
suction process begins.
•
The load may only be lifted when the LED (indicator) lights up green.
•
If the suctioned load is to be released again, the red button
•
The suction process then immediately starts again. This can be interrupted by pressing the green
button
•
The indication of the measured value in the display
suction process) by pressing the button
psi).
•
The digital manometer
with slightly porous materials. If the display shows less than - 0.6 bar (- 8,7 psi), discard
load immediately!
58500014
①
to the ON position to switch on the unit.
⑥
should always be fully charged before each use. Wounding the unit with a battery
③
.
⑤
must be constantly in the operator's field of vision, especially
②
is shown directly in the display.
⑤
can be changed during operation (in the
⑧
(load WLL in kg or lbs // negative pressure in bar or
13 / 16
④
must be pressed.
③
. Press