Operation
4.2.6
Starting up
•
Slide the ON-OFF switch
GREENLINE).
•
The battery status indicator
level.
•
If the battery status indicator
recharged before using the device:
•
The battery
charge level that is too low can result in serious injury and damage due to sudden dropping
of the lifted load!!!
•
The battery can be charged at any time without reducing the battery life.
•
If the holding force begins to decrease noticeably even though the battery is fully charged, check
the rubber foam seal for wear or damage. Do not attempt to lift a load with the unit until the rubber
foam seal has been replaced.
•
Position the device (FXAH-120-GRABO-GREENLINE) on the surface to be lifted.
•
To switch on the vacuum pump and trigger suction of the load, press the green button
the device at the handle for a few seconds with light force against the load to be lifted and the
suction process begins.
•
If the sucked material is to be released again, the red button
•
The suction process then immediately starts again. This can be interrupted by pressing the green
button
•
The manometer
slightly porous materials. If the display shows less than - 0.6 bar (- 8,7 psi), discard
material immediately!
58500016
①
to the ON position to turn on the unit (FXAH-120-GRABO-
②
②
⑥
should always be fully charged before each use. Wounding the unit with a battery
③
.
⑤
must be constantly in the operator's field of vision, especially with
below the power switch lights up to indicate the battery charge
⑥
flashes, the battery
13 / 16
is not sufficiently charged and should be
④
must be pressed to release it.
③
. Press
GB