Installation instructions (translation from original)
SIN 900x M
Safety switch with separate actuator
Conventional thermal current I
Utilization category acc. to IEC
Utilization category acc. to UL/CSA
Direct opening action
Short-circuit protective device
Rated conditional short-circuit current
9.2
Mechanical data
Operation
Minimum actuating radius R
Approach speed V
max
Extraction force
highest measured test force F1max
Holding Force FZh
Ambient air temperature
Storage temperature
Continous vibration
Shock 1
Shock 2
Contact function
Switching principle
Mechanical life
Assembly
Connection
Conductor cross-sections
Cable entrance
Installation position
Protection type
Material
Enclosure
Cover
Emergency release
Key
Escape release
Extension
Actuator head
M12 socket integrated
9.3
Other
Standards
Conformity
Approvals
Doc. # BA001307 – 03/2023 (Rev. B)
R1.311.900x.0
the
min
Test standard
Frequency range
Amplitude
Frequency cycle count
Test standard
Shock amplitude
Shock duration
Number of shocks
Test standard
Shock amplitude
Shock duration
Number of shocks
Wieland Electric GmbH
Brennerstraße 10 – 14
96052 Bamberg
Phone +49 951 9324-0
Fax
+49 951 9324-198
info@wieland-electric.com
www.wieland-electric.com
5 A
AC-15, U
/ I
240 V / 1,5 A
e
e
DC-13, U
/ I
24 V / 1,5 A; 250 V / 0,11 A
e
e
B300 / R300 (same polarity)
Acc. to IEC/EN 60947-5-1, Annex K
4 A gG
400 A
Specifications
Separate Actuator
see chapter 4.5 "Approach radii", p. 11
0,5 m/s
≤ 10 N
2800 N (EN ISO 14119)
1500 N (EN ISO 14119)
-25 °C ... +55 °C
-35 °C ... +80 °C
EN 60068-2-6
10 ... 150 Hz
(0,35 mm / 5 g) at the reference point
20
EN 60068-2-27
30 g
11 ms
3
EN 60068-2-27
10 g
16 ms
1000
See product type, chapter 3 "Identifying by type description", p. 9
4 slow-action contacts
1 × 10
6
Switching cycles
4 × M5 (Tightening torque: 2 Nm)
Screw connection (M3.5; drive Pozi 2; tightening torque 80 Ncm)
2
0,34 ... 1,5 mm
flexible
M20x1.5; see chapter 3 "Identifying by type description", p. 9
For "field installations" in the UL/CSA area.
Use of CU connection cables designed in accordance with NEC
(NFPA 70/79) and CEC (CSA C22.1).
any
IP67 according to IEC/EN 60529 (with suitable screw connection)
Type 6 (UL 50 E / CSA C22.2)
Polyamide PA66/6 GF FR (UL94-V0)
Polyamide PA66/6 GF FR (UL94-V0)
Polyamide PA66/6 GF FR
Stainless steel
Aluminium / Stainless steel
Aluminium / Stainless steel
Die-cast zinc / Surface: nickel
Brass
Specifications
EN 60947-5-1
UL 508 18th Edition, CSA-C22.2 No. 14-18
EN ISO 14119
EN ISO 13849-1
2006/42/EG (Machine Directive)
2012/19/EU (EU-WEEE II); WEEE-Reg.-Nr. DE 50560927
Supply of Machinery (Safety) Regulations 2008, 2008 No. 1597
CE
UKCA
SIN 900x M
2 A
DC-13, U
/ I
24 V / 1,5 A
e
e
30 V / 2 A general use
2 A gG
15 EN

Publicité

loading

Ce manuel est également adapté pour:

Sin 9005R1.311.9005.0