12 - DIAGNOSTICS
(READING OF EVENT)
To perform a diagnostic on the operation of the installation, the
control unit stores events that interfere with the normal operation
of the automation.
The events are stored according to the level of importance that is
Ev.M
set for the
parameter.
Using the V2+ software (connection via USB), it is possible to
display the last 127 events.
Using the display of the control unit, it is possible to display the
last 32 events.
To access the menu follow these instructions:
1. Press and hold down the MENU key until the
on the display
2. Release the MENU key: the display will show
3. Press the DOWN key twice: the display will show
4. Press the MENU key to display the list of events
EvEn
CAnC
n-32
n-02
n-0 1
ES C
All manuals and user guides at all-guidesbox.com
-Cnt
appears
tot
EvEn
no
Si
E 0 03
E 00 1
S= i n
A
The events are numbered in ascending order from
n-01
(
is the most recent,
press the MENU key to display the following information:
A -
EVENT CODE
The code displayed is used to define the type of event that
has occurred (see the dedicated table on the next page)
B -
STATE OF AUTOMATION
S=FE
gate stopped
S=AP
gate opening
S=PA
gate paused
S=Ch
gate closing
S=in
control unit initializing
S=M
control unit in programming phase
S=Sb
control unit on stand-by
C -
CYCLES AFTER THE EVENT
This counter displays how many cycles have been completed
after the event has occurred.
has occurred in the current cycle which has been stopped
C-99
means 99 or more cycles were completed after the
event
D -
REPETITIONS
This counter shows how many times the event has repeated
in the same cycle (
once)
To exit the menu, select
To delete all stored events, select
Si
select
to confirm
C - 0 0
C - 0 0
B
C
- 48 -
n-01
n-32
the oldest); select the event and
C-00
means that the event
r 0
means that the event occurred only
ESC
and press the MENU key to confirm
CAnC
, press the MENU key and
r
r
D
n-32
to
2
4