Télécharger Imprimer la page

Trafimet SACIT Pantera Manuel D'utilisation Et D'entretien page 9

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 65
1.7
Recommended shade number according to EN 379
Welding
process
0.5
1
2.5
Covered elec-
trodes
MIG (steel)
MIG (light alloys)
TIG
MAG
5 6 7 8 9
Plasma welding
Plasma cutting
2.
PART 2 - COMPLETE PANTERA AIR SYSTEM
2.1
Introduction
Pantera Air System is a combined face and respiratory protection device for increased safety and
comfort during welding. Please read these instructions carefully before unpacking.
The respiratory protection system must not be used:
• In a dangerous environment for the user's health and safety, an environment with an oxygen level
below 17% or containing unknown substances.
• In confined or non-ventilated environments such as curves, etc.
• Near flames or projections.
• In an explosion risk zone.
• In a very windy zone.
• If the filter is not installed.
2.2
Approvals
The system complies with the requirements of PPE Regulation 2016/425 and European Standard EN
12941: 1998 +A1:2003+A2:2008 TH3 R SL. The Respiratory System is designed to provide a supply
of filtered air via a breathing tube to a welding headpiece. The equipment can be used in environment
that requires a class TH3 P breathing protection device. It protects against particulate contamination.
All components used in Respiratory System must be manufacturer approved parts, and must be used
in accordance with the instructions in this manual.
1.
The approval is not valid if the product is incorrectly used together with non-approved parts
or components.
2.
Only the particle filter and pre-filter can be used together with this system. Filters from
other manufacturers should under no circumstances be used.
2.3
Warning and limitations to use
Before each use, inspect the Respiratory System for damage and verify that it operates properly.
Before using the Respiratory System, test air flow to verify it is providing an adequate volume of air.
Always wear the Respiratory System and do not remove the head top or turn off the air filter unit until
outside the contaminated area. Otherwise, there is a risk of high concentration of CO2 and oxygen
level in the head top will fall, thus little or no protection is given.
If you are not sure about the concentration of pollution, or about equipment performance, ask the
industrial safety engineer.
5
10 15 20 30 40 60 80 100 125 150 175 200 225 250 275 300 350 400 450 500 550
9
9
10
10
11
Amperes
10
11
10
11
10
11
11
12
10
11
12
12
13
11
12
12
13
12
13
12
13
14
13
14
13
14
14
13
14
14
15
15
15
9

Publicité

loading

Ce manuel est également adapté pour: