USER AND MAINTENANCE MANUAL
No air flow, no alarm
Battery run time is too short
Air supply to hood smells
unusual
Supply insufficient air to
hood
PANTERA AIR SYSTEM Marking
EN 12941: 1998 +A1:2003+A2:2008
TH3 P R SL
CE1024
Marking explanation:
EN12941:1998 +A1:2003 +A2:2008 = Directive reference
TH3 = Filter model (Protection level)
P = Particle filter / R = Reusable type of particle filters
SL = Tested against particles of liquid and solid.
CE = Conformity mark / 1024 = Certification authority
Notified Body: Vyzkumny ustav bezpecnosti prace, v. v. i., Jeruzalémská 1283/9,
110 00 Praha 1, Czech Republic (Notified body number 1024)
2797
16
1. No power
2. Battery contact damaged
1. Battery is not fully charged
2. Filter is blocked
3. Battery is damaged
1. Filter broken
2. Tube broken
3. ADF helmet broken
1. Breathing tube broken off
2. Breathing tube broken
3. Filter is blocked
CE mark followed by number of notified body who
carried out module D surveillance.
Charge the battery
Check battery contact
Charge the battery
Remove obstruction, change filter
Change battery
Leave current area immediately.
1. Change filter
2. Change tube
3. Change ADF helmet
1. Check tube connection to hood and
Respiratory system unit
2. Change breathing tube
3. Remove obstruction, change filter

Publicité