Télécharger Imprimer la page

ITW MBM EF411 Instructions Pour Le Fonctionnement page 40

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 46
ROUTInE MAInTEnAnCE
Troubleshooting
N.B.! Whenever the appliance does not work properly, try to solve the less serious
problems using this table.
FAULT
The appliance does not turn on.
Water does not reach the pasta
cooker tank.
Water does not drain from the
cooking cavity.
The inner walls of the tank are
covered with limestone.
The cooking cavity is stained.
The gas appliance does not turn
on.
The light indicators do not turn
on.
N.B.! If the problem cannot be resolved, turn the appliance off and shut all the
supply valves. Then contact customer service.
THE PRESENT MANUAL IS PROPERT Y OF THE MANUFACTURER. ANY REPRODUCTION, EVEN PARTIAL, IS PROHIBITED.
All manuals and user guides at all-guides.com
PoSSIBLE CAUSE
The master switch is not
connected
The residual current device
or circuit breaker has tripped
The waterworks gate valve
is shut.
The drain is clogged.
The water is too hard; the
softener is finished.
Quality of the water
Ineffective detergent
Insufficient rinsing
Gas valve shut.
Air inside pipes.
The master switch is not
connected
The residual current device
or circuit breaker has tripped
- 41 -
41
INTERVENTIoN
Connect the master switch
Switch the residual current
device and/or circuit breaker
back on
Open the waterworks gate
valve.
Clean the drain filter.
free the drain from residues.
Connect the appliance to a
water softener.
Regenerate the water
softener.
Descale the cooking cavity.
filter the water (see water
softener)
Use the recommended
detergent
Rinse once again
Open the gas valve
Repeat the ignition
operations
Connect the master switch
Switch the residual current
device and/or circuit breaker
back on

Publicité

loading

Ce manuel est également adapté pour:

Mbm ef911