5.2 Loading the single-fastener tool
1. Push the fastener into the tool from the front until it is held in place in the tool by the fastener's washer.
2. Push the cartridge strip, narrow end first, into the grip of the tool from below until the full length of the
cartridge strip is inside the tool. If you wish to use a cartridge strip in which some of the cartridges have
already been used, start pulling the strip up and out the top of the tool by hand until the first unused
cartridge is in place in the cartridge chamber.
5.3 Setting the power level
1. Press the power regulator release button.
2. Turn the power regulating wheel to set the power level you require.
3. Check the quality of the fastening in accordance with Hilti standards.
Note
Select a cartridge power level and power setting to suit the application.
If you have no previous experience of using the tool, always begin with the lowest power.
5.4 Driving fasteners with the single-fastener tool
1. Position the tool.
2. Hold the tool perpendicular to the working surface and then press it against the surface.
3. Press the trigger to drive the fastener.
5.5 Unloading the single-fastener tool
1. Pull the cartridges out of the tool.
2. Pull the fastener out of the tool.
5.6 Switching Bluetooth on and off
▶ Press and hold the pushbutton for 1-2 seconds to switch on Bluetooth.
Note
Bluetooth switches itself off automatically after 2 minutes.
5.7 Resetting the cleaning indicator
▶ Press and hold the pushbutton for 10-12 seconds to reset the cleaning indicator.
Note
The cleaning indicator consists of 5 bars. Each bar stands for 500 fastenings.
5.8 X-FCM grating fastener
1. Position the grating.
2. Drive the threaded stud into the steel beam. Use the centering sleeve to help ensure easy centering of
the fastener. Measure the stud stand-off distance by checking the depth of penetration with the gauge.
3. Screw on the retaining flange.
◁ Torque: 5-8 Nm
5.9 X-FCP checker plate fastener
1. Drill or punch the holes in the checker plate.
Note
Observe the following minimum dimensions and distances:
A = 18-20 mm (0.70''-0.7'')
B ≥ 25 mm (≥ 0.98'')
2. Position the checker plate.
3. Drive the threaded stud through the predrilled or punched hole. Measure the stud stand-off distance by
checking the depth of penetration with the gauge.
4. Screw on the retaining flange.
◁ Torque: 5-8 Nm