Télécharger Imprimer la page

Desoutter ESP-C 110 V Mode D'emploi page 10

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
6159934960
Issue no: 07
6. I/O CONNECTIONS
An I/O connector with 10 pins is set up on the
rear panel of the controller.
6.1. Input
Pin
Function
1
COM 0VDC
2
START
3
REVERSE
4
STOP
5
NOT USED
6.2. Output
Pin
Function
6
TORQUE
7
LEVER
8
ERROR
9
COM0VDC
10
NOT USED
The output signals are protected.
An overload or a short circuit on the
signals triggers the controller to stop. To
reset the signals, you must turn off the
controller for a minimum of 6 seconds,
check the connectors and then start up
again.
10 / 190
Comment
Common pin for all input signals; the signal must be taken between the pin
1 (0 VDC) and the other pins (2,3 and 4)
Remote start of the unscrewing cycle.
Right step tightening with a stop at the torque.
Remote start of the untightening cycle. No control of the torque reached.
Motor stop, "EXTERNAL STOP" displayed on the screen, the motor stops
and starts after the contact opening.
Not used
Comment
Torque reached signal. 24 V-20 mA, max 0.5 W
Lever start up signal when the lever is pressed or a "START" signal is
transmitted. No signal during the untightening.
24 V-20 mA, max 0.5 W
Error signal is actuated when
- The torque is reached during the "slow start" phase
- The torque is reached during the "approach speed" phase
- The selected tightening time has elapsed without having reached the
torque
24V 20mA,max 0.5W
Common pin for all output signals; the signal must be taken between the
pin 9 (0 VDC) and the other pins (6,7 and 8)
Not used
03/2022

Publicité

loading