ENGLISH
1. GENER L
bout this document
The language of the original operating instructions is french. ll other
languages of these instructions are translations of the original
operating instructions.
These installation and operating instructions are an integral part of
the product. They must be kept readily available at the place where
the product is installed. Strict adherence to these instructions is a
precondition for the proper use and correct operation of the
product.
These installation and operating instructions correspond to the
relevant version of the product and the underlying safety standards
valid at the time of going to print.
EC declaration of conformity:
copy of the EC declaration of conformity is a component of these
operating instructions.
If a technical modification is made on the designs named there
without our agreement, this declaration loses its validity.
2. S FETY
These operating instructions contain basic information which must
be adhered to during installation and operation. For this reason,
these operating instructions must, without fail, be read by the service
technician and the responsible operator before installation and
commissioning.
It is not only the general safety instructions listed under the main
point "safety" that must be adhered to but also the special safety
instructions with danger symbols included under the following main
points.
2.1 Indication of instructions in the operating instructions
Symbols :
General danger symbol.
Danger due to electrical voltage.
NOTE:
Signal words:
D NGER!
cutely dangerous situation
Non-observance results in death or the most serious of injuries.
W RNING!
The user can suffer (serious) injuries. 'Warning' implies that (serious)
injury to persons is probable if this information is disregarded.
C UTION!
There is a risk of damaging to the product/installation.
'Caution' implies that damage to the product is likely if the
information is disregarded.
NOTE: Useful information on using the product. It draws attention to
possible problems.
2.2 Personnel qualifications
The installation personnel must have the appropriate qualifications
for this work.
2.3 Danger in the event of non-observance of the safety instructions
Non-observance of the safety instructions can result in risk of injury to
persons and damage to product/installation. Nonobservance of the
safety instructions can result in the loss of any claims for damages.
In detail, non-observance can, for example, result in the following
risks:
• Failure of important functions of the product/installation,
• Failure of specified maintenance and repair procedures,
• Risks to persons through electrical, mechanical and
bacteriological effects,
• Property damage.
2.4 Safety instructions for the operator
The existing directives for accident prevention must be adhered to.
Danger from electrical current must be eliminated.
Local directives or general directives [e.g. IEC, VDE etc.] and local
power supply companies must be adhered to.
This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to ensure that they do not play with
the appliance.
2.5 Safety instructions for inspection and installation work
The operator must ensure that all inspection and installation work is
carried out by authorised and qualified personnel, who are
sufficiently informed from their own detailed study of the operating
instructions.
Work to the product/installation must only be carried out when at a
standstill. It is mandatory that the procedure described in the
installation and operating instructions for shutting down the
product/unit be complied with.
2.6 Unauthorised modification and manufacture of spare parts
Modifications to the product are only permissible after consultation
with the manufacturer. Original spare parts and accessories
authorised by the manufacturer ensure safety. The use of other parts
can nullify the liability from the results of their usage.
2.7 Improper use
The operational safety of the supplied product is only guaranteed
for conventional use in accordance with section 4 of the installation
and operating instructions. The limit values must on no account fall
under or exceed those specified in the catalogue/ data sheet.
3. TR NSPORT ND STOR GE
When receiving the material, check that there has been no
damage during the transport. If any defect has been stated, take all
necessary steps with the carrier within the allowed time.
C UTION! If the delivered material is to be installed later on,
store it in a dry place and protect it from impacts and any
outside influences (humidity, frost, etc...).
4. PRODUCTS ND CCESSORIES
4.1 pplications
Pumps for lifting of domestic waste water containing particle lower
than 30 mm.
For fixed installation in a sump or a tank.
4.2 Description (See FIG. 1)
1 : Check valve adapted to the conveyed medium.
2 : Isolating valve.
3 : Overflow audible signal.
4 : Pump lifting chain.
5 : Motor cable - length 10 m.
4.3 The pump
- Submersible monobloc electropump.
- Centrifugal single-stage with vortex impeller.
- horizontal or vertical (with bend) discharge port .
- Tightness with lip seal.
8