8. OPER TING TROUBLE
TTENTION! Before any intervention disconnect the
pump.
DEF ULTS
8.1. THE PUMP F ILS TO ST RT
8.2. THE PUMP F ILS TO
DELIVER OR DELIVERS
TOO LITTLE
8.3. THE PUMP TRIPS OUT
9. SP RE P RTS
Spares should be ordered through local trade outlets and/or
the Salmson- fter-sales Service.
To avoid queries and incorrect orders, all the data on the
name plate must be indicated when ordering.
C USES
a) No current:
b) Winding or cable open-circuit:
c) Rotor stalled
(the motor "growls"):
a) Discharge pipe obstructed:
b) Impeller obstructed by particles:
c) The check valve is mounted
upside down:
a) Faulty electrical installation:
b) Pump stalled:
c) The pump is hard to turn:
a) Check the line. Replace the fuses if necessary.
Close the overload release or the switch of the control box.
b) Check the resistances between the cable ends ; if necessary replace
the cable. (Caution: in case of replacing, reconnect correctly the
supply wires according to the colours).
c) Dismantle the impeller and clean it.
a) Remove the pipe and clean it.
b) (See 8.1 - c).
c) Check it.
a) Check the whole electrical installation.
b) (See 8.1 - c).
c) (See 8.1 - c).
10
REMEDIES