Operation
The heater switches on automatically straight
after reaching the flow rate over 2,5 l/min.
The temperature control system selects an
appropriate heating
power depending on the rate of flow, tem-
perature setting (set with the use of a knob
on the front case) and the temperature of
water in the mains.
There are two indicators on the case:
-
green – power supply "on",
-
red – heating "on".
Other modes are shown by flickering green light.
Number of impulses
(green indicator)
1
2
3
4
PL;DE;GB;FR;RU-051AB/f.517
The unit was switched off because the temperature has exceeded the
maximum value (fault signal will not disappear until the appropriate rate
of water flow is reached).
The unit was switched off by a master appliance.
The inlet temperature sensor failure.
The unit was switched off because the air bubbles in the heating box (the
unit will not heat again until the fault is resolved and the appropriate rate
of water flow is reached).
description
GB
13