M O U N T I N G I N S T R U C T I O N S
All rights reserved. Subject to change without notice.
1
About this document
These mounting instructions apply for the RLY3-OSSD1 safety relay.
2
Safety information
DANGER
Hazard due to lack of effectiveness of the protective device
In the case of non-compliance, it is possible that the dangerous state of the
machine may not be stopped or not stopped in a timely manner.
Please observe the safety notes provided.
b
For more information about how to work with the protective device, refer to the
machinery documentation or the operating instructions for the protective
device.You can call up the EU declaration of conformity and the current operating
instructions for the protective device by entering the part number in the search
field at
www.sick.com
(part number: see the type label entry in the "Ident. no."
field).
3
Mounting procedure
Prerequisites
Mounting is done in accordance with EN 50274 and electrical installation in
accordance with IEC 60204-1 in the control cabinet with enclosure rating
IP54.
Mounting is done on a 35 mm mounting rail (IEC 60715).
The mounting rail is connected to the functional earth.
The safety relay is installed in a vertical orientation (on a horizontal mounting
rail).
There is at least 50 mm of space for air circulation above and below the
safety relay.
There is at least 25 mm of space in front of the safety relay (front side). More
space may be needed depending on the connections.
Approach
Attach safety relay to mounting rail.
b
4
Device connection
Prerequisites
Contact fuse with safety fuse gG or circuit breaker C: 6 A, maximum short-
circuit protection I ≤ 400 A.
The ground connection of all connected devices must have the same poten‐
tial as A2.
All connected devices and the reset pushbutton comply with the required
category in accordance with ISO 13849-1 and SILCL in accordance with IEC
62061 (e.g. outputs which detect cross-circuit, shielded single sheathed
cables, separate installation).
Pin assignment of the terminals
Terminal
Description
13, 14
Enabling current path
1) 2)
23, 24
Enabling current path
1) 2)
31
Feedback current path, 24 V DC
32
Feedback current path, for connection to the EDM input of
the basic device
I1
CH1 input (safety capable input for OSSD 1)
I2
CH2 input (safety capable input for OSSD 2)
A2
Voltage supply 0 V DC
The enabling current paths must be supplied by the same voltage supply.
1)
The enabling current path and external device monitoring (EDM) must be wired within the
2)
control cabinet.
8020861/ZXO5/2018-11-15/de, en, fr
With single-channel base device: Connect jumper between I1 and I2.
3)
e n
5
Status indicator (LED)
NOTE
SICK recommends cutting out the table below and attaching it to the wall of
the control cabinet.
Operational statuses
LED
CH1
CH2
6
Data sheet
See the operating instructions for a full overview of the technical data.
Operating data
Safety capable inputs (I1, I2)
Input voltage HIGH
Input voltage LOW
Switching voltage for feedback current path
31, 32
Switching voltage for enabling current paths 13, 14, 23, 24
At altitudes below 2,000 m above sea
level
At altitudes 2,000 m above sea level ...
4,000 m above sea level
Interfaces
Connection type
Wire cross-section
Single wire (1×)
Fine wire (1×)
Fine wire with ferrule with plastic collar
(2×, same cross-section)
Fine wire with ferrules with or without collar
(1×)
For UL and CSA applications
3)
Status
Possible cause
Voltage on I1
O Green
O Green
Voltage on I2
ReLy OSSD1
24 V DC (15 V DC ... 30 V DC)
0 V DC (–3 V DC ... 5 V DC)
15 V DC ... 30 V DC
15 V AC ... 30 V AC
10 V DC ... 250 V DC
10 V AC ... 250 V AC
10 V DC ... 150 V DC
10 V AC ... 150 V AC
ReLy OSSD1
Spring terminal
0.2 mm
... 1.5 mm
2
0.2 mm
... 1.5 mm
2
≤ 0.5 mm
2
0.25 mm
2
... 1.0 mm
26 AWG ... 14 AWG
(use only copper wire (60/75 °C))
2
2
2
ReLy OSSD1 | SICK
2