ELECTRICAL CONNECTIONS AND PROGRAMMING
The control panel is powered by 230 V AC, with 50/60Hz frequency. The control devices and accessories run on 24 V.
⚠ The accessories must never exceed 15 W overall.
Fuses
Type
Line (mA)
Accessories (mA)
Description of parts
1.
230 V AC power-supply terminals
2.
Transformer connection terminals
3.
Line fuse
4.
Accessories fuse
5.
24 V power-supply terminals for control and
safety devices
6.
CRP connection terminals
* COM speed is fi xed at 38400 baud
7.
AF card connector
8.
RSE card connector
9.
Built-in antenna
L2T
L1T
Power supply
10
0V
20V
J8
M1
400
630
10. DIP for selection of functions with RSE (to select
the peripheral number from 1 to 32 for each
electronic board in case of system with several
operators).
11. Programming button
12. Battery-charger connector
13. MOTOR 1 and MOTOR 2 sockets
14. Power on signalling LED
15. Programming warning LED
16. Dip-switches for selecting functions and program-
ming
⑥ ⑦ ⑧
11
2
3
4
CX
A
B
GND
Terminals for powering 24 V AC accessories.
Maximum allowed power: 15 W.
10
11
2
3
4
CX
M3
J7
R25
R9
R22
R3
R23
C13
C12
C11
Z4
Z3
CH1
A
B
GND
M6
R6
C17
Z2

Publicité