There are two possible points to pass the power-supply and accessories control cables: either on the anchoring base through
the existing slits (option 1), or on the side cap which is provided with pre-formed holes (option 2).
Connect the ground to both gearmotors.
-
-
Option 1
Option 2
LEFT
HAND MOTOR
RIGHT
HAND MOTOR
Command and control devices
RSE card
The AF and RSE cards must be fitted
into the control board AFTER CUTTING
OFF THE MAINS POWER.
N.B.: the basic control board recognizes
them only when it is powered up.
AF card
CRP - Came Remote Protocol.
Connection to the home automation
system.
OPEN-STOP function (NO contact)
CLOSE-STOP function (NO contact)
⚠ If on the 2-3 connected button, the PARTIAL OPENING function is activated via DIP-switch, then the button connected to
2-4 will automatically operate as a sequential OPEN-STOP-CLOSE-STOP command.
⚠ If MAINTAINED ACTION is activated via DIP-switches, the two buttons will automatically operate as OPEN ONLY and CLOSE
only respectively.
⚠ When the MAINTAINED ACTION function is active, the PARTIAL OPENING function cannot be set.