Télécharger Imprimer la page

CAME VLR01DX Manuel D'installation page 28

Masquer les pouces Voir aussi pour VLR01DX:

Publicité

Les langues disponibles

Les langues disponibles

Unfoldable type of transmission arm
A - Minimum space between the inner fi xture and the shutter
B - Recess width (min/max)
One leaf, without VLR01xx batteries
One leaf, with VLR01xx+VLR05 batteries
Two leaves, without VLR02 batteries
Two leaves with VLR02+VLR05 batteries
F - Width of internal panel (min/max)
The angle
must always exceed 90°; make sure to install a simple strike plate
For this application, make sure to fi t a corner protection
GENERAL INSTRUCTIONS FOR INSTALLING
⚠ Only skilled, qualified staff must install this product in full compliance with the law in force.
Preliminary checks
make sure that the point, where the operator is anchored, is protected from any impacts and that the anchoring surface is
solid enough, and that proper tools are used (that is, screws, dowels, and so on); suitable;
Set up suitable conduits and tubes to safely run the electrical cables through and to protect them from mechanical damage.
Remove the shutters opening stops and replace them with strikers.
Make sure the angles between the two leaves always exceeds 90°.
Tools and materials
Make sure you have all the tools and materials you will need for installing in total
safety and in compliance with applicable regulations. The figure shows some of the
equipment installers will need.
Cable types and minimum thickness
Connection
Power supply to control panel 230 V
Accessories powered at 24 V
Command and safety device
Home & building automation connections
☞ If cable lengths differ from those specified in the table, establish the cable sections depending on the actual power draw of
the connected devices and according to the provisions of regulation CEI EN 60204-1.
For multiple, sequential loads along the same line, the dimensions on the table need to be recalculated according to the actual
power draw and distances. For connecting products that are not contemplated in this manual, see the literature accompanying
said products
One or two-leaved jointed double-panelled shutter
Cable type
FROR CEI 20-22
CEI EN 50267-2-1
CAT5 - U/UTP - AWG24
VLR08
130
500 / 1050
750 / 1050
820 / 2100
970 / 2100
140 / 170
for this.
for the arm.
1 < 10 m
3G x 1.5 mm
2 x 0.5 mm
2 x 0.5 mm
VLR09
160
500 / 1050
750 / 1050
900 / 2100
970 / 2100
170 / 240
.
Cable length
10 < 20 m
20 < 30 m
2
3G x 2.5 mm
2
3G x 4 mm
2
2 x 0.5 mm
2
2
2 x 0.5 mm
2
2 x 0.5 mm
max 1200 m
2
2 x 1 mm
2
2

Publicité

loading

Ce manuel est également adapté pour:

Vlr01sxVlr02