1.3. Authorized operators
The product is aimed at expert operators who share
among end-users and specialized technicians (see
pictograms above).
It is forbidden for the end user to perform
GB
interventions
technicians.
responsible for damage resulting from non-
compliance with this prohibition.
1.4. Warranty
Conditions of Sale.
Manufacturer).
the instructions and standards described in this
manual.
(see § 1.5).
- In the event of technical assistance interventions
manufacturer.
- If the maintenance provided in this manual is not
performed.
1.5. Technical support service
requested from CALPEDA PUMPS (see § 1.2) or
one of its resellers.
2.
TECHNICAL DESCRIPTION
Fixed speed lifting stations with up to 2 pumps,
isolation valves and non-return valves at discharge.
micro-station exit, rainwater or drainage water.
2.1. Intended use
for contaminated water. For non-explosive or
the environment, not aggressive for the pump
napkins,
tampons,
packaging, masks, wipes, etc., biodegradable
or not). Otherwise, the use of a screen basket is
recommended for stations with this option.Liquid
temperature depending on model.
2.2. Improper use
The device has been designed and constructed
It is forbidden to use the appliance for
in this manual.
Lifting stations should not be used in
locations where there is a risk of explosion
or danger of ignition.
We can not be held responsible for the use of lifting
stations units with liquids that could be dangerous
Page 8 / 24
reserved
for
specialized
The
manufacturer
condoms,
cotton
Rev. 2111
and effectiveness of the device ; CALPEDA
PUMPS can not be held responsible for failures or
accidents due to non-observance of the prohibitions
presented above.
is
not
2.3. Marking
under the cover of the lifting station.
Serial number
Article number
3.
TECHNICAL FEATURES
3.1. Technical data
Overall dimensions and weight (see technical
catalogue).
Nominal speed 2900 rpm
Protection IP X8
Geometric height : 2 to 18m depending on the
model
Discharge length : 15 to 500m linear depending on
the model.
3.2. Operating conditions
conditions are respected.
- Floating voltage rate +/-5% max
- Ambient temperature +35°C
3.3. Product overview
- 1 to 2 pumps
- 1 discharge shut-off valve (1 per pump).
- 1 discharge manifold (double pump station).
The lifting stations must be equipped with electrical
buds,
tripping devices to protect the line from motor
malfunctions.
4.
SAFETY
4.1. General behavior standards
to acknowledge all the information about
transportation to disposal.
with all applicable standards and laws, including
Instructions techniques - Postes de relevage
Example plate pump
230V 1~50 Hz