5
Electrical installation
Regenerative power supply module EMB9343
Power connections
Wiring
Stop!
ƒ
ƒ
L1
PE
0
Fig.13-10
Screws for cover
Mains cable
Supply cables of the regenerative power supply module
Supply cables for devices in the DC-bus connection
Bridges for internal mains synchronisation
(must be removed in case of external mains synchronisation)
Cable for external mains synchronisation
120
Bolt the cables to X4 (blue) and X10 (red) with a distance of at least 5.5 mm.
The cables L1A, L1B, X4 and X10 are additional electrical connections
between the mains filter A and the regenerative power supply module
EMB9343. They must be bolt at the regenerative power supply module at
the threaded bolts with the same designation.
1
L2
L3
2
L
Wiring of the power connections EMB9343
3
2 2
2 2 2 3
L1
L2
L3
PE
+UG
-UG
L1A
L1B
2
2
X4
}
X10
4
5
9340vrm010