Install Ductwork; Prepare The Installation - Broan Elite E662 Guide D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1. INSTALL DUCTWORK

Plan where and how the ductwork will be installed. Install proper-sized ductwork, elbows and roof or wall cap for the
type of blower you are installing. Use 2" duct tape to seal duct joints.
NOTE: When performing vertical exhaust ductwork, there must be at least 14" high free inside cabinet in order to
allow cabinet blower installation.
The minimum hood distance above cooktop must not be less than 24". A maximum of 30" above cooktop is
highly recommended for best capture of cooking impurities.
Distances over 30" are at the installer and users discretion.
Roof cap
Wall
cap
HH0045A

2. PREPARE THE INSTALLATION

Make sure that the following items are included:
- Hood
- Accessories:
• Filters (2 for 30'' and 36'' width hoods, 3 for 42'' width hood)
• Cabinet blower including left and right flow deviators (assembled to cabinet blower)
• Electrical cable with 3-prong receptacle (inside one filler)
• 3
" x 14" adapter/damper (inside one filler)
1
4
• Bag of parts (inside one filler) including:
(2) wire clamps, (5) #8 x
Parts sold separately:
- Halogen lights (MR16, GU10, 120V, 50W)
- Transition 3
1
" x 14" to 8'' round model # 459 (optional), transition 3
4
adaptor/damper 3
1
" x 14" to 3
4
page 1 for a complete list of venting options and model number.
NOTES: 1. During installation, protect countertop and/or cooktop.
2. If the bottom of the cabinet is recessed, attach three 1" width wood strip (not included). Refer to figure
below for wood strips proper location.
3¼" x 14" duct
OR 3¼" x 10"
3¼" x 14" to
3¼" x 10" adaptor
model T461 (optional)
Cabinet blower
Hood
24" minimum above
cooking surface
1
" screws, (3) wire connectors, (9) #8 x
2
1
" x 10" model T461 (optional), ducts, elbows, dampers, wall or roof caps. Refer to
4
CABINET BOTTOM
1"
1"
1¾''
HO0045A
Roof cap
Wall
cap
HH0046A
3
" screws
8
1
" x 14" to 7'' round model # T460 (optional),
4
1"
10¼''
1¾''
- 2 -
7" OR 8" round duct
Transition model 459
3¼" x 14" to 8" OR
model T460
3¼" x 14" to 7"
Cabinet blower
Hood
24" minimum above
cooking surface