Select Blower Option And Install Ductwork; Prepare The Installation - Broan Elite E662E Mode D'emploi

Masquer les pouces Voir aussi pour E662E:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1. SELECT BLOWER OPTION AND INSTALL DUCTWORK

Either an in-line or exterior blower may be used with this hood. The Broan Elite model E662E must be installed with
blower models HLB3, HLB6, HLB9, HLB11, 331H, 332H, 335 or 336 only. Other blowers cannot be substituted.
(Blowers sold separately).
Plan where and how the ductwork will be installed.
If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1 up to 6, 8 and up
of this manual.
Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. Use 10'' round
ductwork. Use 2" duct tape to seal duct joints.
The minimum hood distance above cooktop must not be less than 24". A maximum of 30" above cooktop is
highly recommended for best capture of cooking impurities.
Distances over 30" are at the installer and users discretion.
10" round duct
In-line blower
24" minimum
above
cooking surface
HH0059A
MODEL HLB3, HLB6, HLB9 OR
HLB11 IN-LINE BLOWER
TYPICAL DUCTWORK

2. PREPARE THE INSTALLATION

Make sure that the following items are included:
- Hood
- Accessories:
• Filters (2 for 30'' and 36'' width hoods, 3 for 42'' width hood)
• Bag of parts (inside one filler) including:
(2) wire clamps, (5) #8 x ½" screws, (3) wire connectors, (9) #8 x
Parts sold separately:
- In-line blower HLB3, HLB6, HLB9 or HLB11 (all include transition)
- Exterior blower model 331H, 332H, 335 or 336
- Halogen lights (MR16, GU10, 120V, 50W)
- Ducts, elbows, dampers, wall and roof caps. Refer to page 1 for a complete list of venting options and model numbers.
NOTES: 1. During installation, protect countertop and/or cooktop.
2. If the bottom of the cabinet is recessed, attach three 1'' width wood strip (not included). Refer to figure below
for wood strips proper location.
Roof cap
Wall
cap
Hood
CABINET BOTTOM
1"
1"
1
¾
' '
HO0045A
Exterior blower
HH0047A
MODEL 331H, 332H, 335 OR 336
TYPICAL DUCTWORK
3
/
" screws
8
10¼''
1"
1
¾
' '
- 2 -
10" round duct
Hood
24" minimum above
cooking surface
EXTERIOR BLOWER

Publicité