DNCKE/KEC
5.2.2
Functional tests
Functional test when used as a holding device (clamping function)
The frequency (or testing interval) of functional tests is to be determined dependent on the application / risk
evaluation. At least once or month or every 100,000 switching cycles unless C-type standards or other regu
lations require more.
Instructions for performing the structural test (è 6.4 Clamping force test).
5.2.3
Creating a tubing connection to the clamping unit
In case of use in normal ambient atmosphere (without particles):
Remove covers (if present) from the compressed air supply
ports.
Remove dirt particles and foreign matter from the ports and
tubing lines.
Use the shortest suitable tubing lines. This will reduce switching
times.
Create tubing connections between the supply ports of the
clamping unit 2 and those of the cylinder 1.
Size
Supply port for clamping unit
Supply port for cylinder (DNCKE only)
Tab. 3
To prevent dirt particles from entering the pneumatic system when
used in ambient air with fine particulate matter or fine mist:
Use a barbed fitting (e.g. QS-CM-M5) instead of the filter nipple
in the exhaust channel 7 of the spring interior.
Run hose into an area with clean ambient atmosphere.
Festo – DNCKE/KEC – 1606a English
KEC
Fig. 10
DNCKE
40
KEC
16
2
G 1/8
1
G 1/4
Fig. 11
2
1
DNCKE
63
100
20
25
G 1/4
G 3/8
G 3/8
G 1/2
7