EN
Select the charging program suitable for the type of house battery used based on the battery manufacturer's specifi-
cations, the information on the charging curves (see
data
). The specified charging times apply to an average ambient temperature of 20 °C.
Slide the DIP switches to the position shown in the table below to set the charging program for the respective
type of house battery.
Table 2: Charging curve configuration
DIP switch po-
sition (gray)
1
2
3
ON
1
2
3
ON
1
2
3
ON
1
2
3
ON
1
2
3
ON
1
2
3
ON
12
Battery charging function
Function
Charging program
Lead gel batteries
Desulfation off
Lead gel batteries
Desulfation on
AGM batteries
Desulfation off
AGM batteries
Desulfation on
Wet batteries
Desulfation off
Wet batteries
Desulfation on
) and the technical data (see
Maximum
Maintenance volt-
voltage
age (V
maint
(V
)
max
14.3 V
13.6 V
14.3 V
13.6 V
14.8 V
13.6 V
14.8 V
13.8 V
14.4 V
13.5 V
14.4 V
13.5 V
Technical
Desulfation volt-
)
age (V
)
des
–
15.8 V
–
15.8 V
–
15.8 V