Technical Data

EC Low-voltage directive
73/23/EEC and RL93/68/EEC
EC EMC directive 89/336/EEC
EC Machinery safety directive
89/392/EEC
Approvals
Type of cooling
Permissible ambient and cooling-
medium temperature
during operation
during storage
during transport
Installation altitude
Permissible humidity rating
Environmental conditions
acc. to DIN IEC 721-3-3
Pollution degree
Overvoltage category
Degree of protection
Standard
Option
Protection class
Shock protection
Radio interference suppression
Standard
Options
Interference immunity
Paint finish
Mechanical specifications
Vibrations
During stationary use:
Constant amplitude
- of deflection
- of acceleration
During transport
- Deflection
- Acceleration
Shocks (only E, F
and G types of construction)
Miscellaneous
Siemens AG
6SE7087-7KN50
SIMOVERT MASTERDRIVES
EN 50178
EN 61800-3
EN60204-1
UL:
E 145 153
CSA:
LR 21 927
Air cooling with built-in fan
0° C to +40° C (32° F to 104° F)
(up to 50° C see Fig. "Derating curves")
-25° C to +70° C (-13° F to 158° F)
-25° C to +70° C (-13° F to 158° F)
≤ 1000 m above sea level (100 % load capability)
> 1000 m to 4000 m above sea level
(for load capability: see Fig. "Derating curves")
Relative air humidity
climate:
chemical active substances: 3C1
Pollution degree 2 to IEC 664-1 (DIN VDE 0110. Part 1).
Moisture condensation during operation is not permissible
Category III to IEC 664-1 (DIN VDE 0110. Part 2)
EN 60529
IP00
IP20 (only E, F and G types of construction)
Class 1 to IEC 536 (DIN VDE 0106. Part 1)
to EN 60204-1 and to DIN VDE 0106. Part 100 (BGV A3)
to EN 61800-3
No radio interference suppression
Radio interference suppression filter for class A1 acc. to EN 55011
Industrial to EN 61800-3
For interior installation
to DIN IEC 68-2-6
0.075 mm in the frequency range 10 Hz to 58 Hz
9.8 m/s² in the frequency range > 58 Hz to 500 Hz
3.5 mm in frequency range 5 Hz to 9 Hz
9.8 m/s² in frequency range > 9 Hz to 500 Hz
to DIN IEC 68-2-27 / 08.89
30 g. 16 ms half-sine shock
The devices are ground-fault protected, short-circuit-proof and idling-
proof on the motor side
Table 11-1
General data
Operating Instructions
≤ 95 %
during transport and storage
≤ 85 %
during operation (moisture
condensation not permissible)
3K3
Technical Data