Washing By Pressure; Drainage; Forced While Timer Programme Is Running) - Astralpool Modbus Manuel D'installation Et D'entretien

Vanne multivoies automatique basic - capteur de pression analogique
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 21
ENGLISH
A single press starts the routine, which can be cancelled at any time by pressing the button again, so that
the valve returns to the filtering position. During the valve's change of position, the LED of the button
flashes. Once the routine is finished, the valve will return to Filtration.

4.3.3 Washing by pressure

When the valve is in the Filtration position and the pump is running, an automatic washing and rinsing
programme will be carried out when the filter pressure exceeds the pressure set on the pressure sensor
for more than 20s. The LED of the washing position also indicates the activation of the pressure sensor
when the pressure exceeds the set value. See "Adjusting the pressure sensor".
4.4 PROGRAMMING TIMES fOR WASHING AND RINSE.
The filtration time must be programmed using the programming clock installed in the control cabinet.
To programme the washing time, use the corresponding buttons on the programming page to select the
desired time in minutes, with the corresponding LED being illuminated. When the valve is performing
this function, the LED will flash.
To programme the Rinse time, use the keys on the keyboard to select the desired time in seconds, with the
corresponding LED being illuminated. When the valve performs this function, the LED will flash.
If during the wash or rinse function, the timer clock determines the end of the filtering programme, the
valve will be in Filtration and the corresponding LED will indicate a long flash (the programme remains in
the memory). When the programme is re-entered the function will end the programme that was underway
at the time it was stopped. This washing and rinsing memory will only be maintained as long as there is a
power supply. It will not be possible to change these times while the valve is in a washing or rinsing process.

4.5 DRAINAGE

4.5.1 In the filtering position and outside the timer filtering programme.
To perform the operation manually, please follow the instructions below:
Press the waste button on the electronic module for 3 seconds, the valve will now be in the Drainage
position.
Turn the switch in the control box to the "I" position, thus activating the pump and starting the drainage
process.
These operations are to be carried out when the valve is in the "filtration" position. If the wash or rinse
cycles are running, please wait until they have finished.
Appliance users should watch for when this operation finishes. Once the appliance has stopped, proceed
as follows:
In the control panel, briefly press the drainage button
1ºTurn switch to "II" position in the control box in order to stop the pump.
4.5.2 forced while timer program running
Press the drainage button for 3 seconds. The electronic module will stop the pump and the valve will turn
to "WASTE" position. The pump will start up again. To stop the drainage press the button briefly
again.
The module will stop the pump and it will be positioned in Filtration and will activate it again.