5. INSTRUCTIONS fOR REMOVING THE MODULE INSTALLED ON THE VALVE

The valve consists of two sections, the hydraulic part which includes a conventional valve and an automatic
module. The complete valve is disassembled of the filter in the same manner as a manual valve.

5.1 DISASSEMBLY Of THE ELECTRONIC MODULE:

(See illustrations in APPENDIX 1) BEFORE ANY OPERATION IS CARRIED OUT ON THE VALVE, IT MUST BE
DISCONNECTED FROM THE POWER SUPPLY.
Remove the four screws which hold the cover (1) in place. (Fig. 2).
Disconnect all input wires to the module (AAPPENDIX 1 - Fig. 8).
WARNING: All mains power supply connections must be removed first.
Refit the cover 1 (Fig. 2).
Remove the three screws (11) which hold the module in place on the valve (Fig. 3). Carefully remove the
module in an upwards direction.
Protect inside suitable packaging to prevent any damage and send it to the manufacturer. From this point
there are two possibilities:
1. Replacement of the module.
2. Temporarily convert the system to manual valve operation.

5.2 INSTRUCTIONS fOR INSTALLING THE MODULE ON THE VALVE.

The manufacturer will ship the valve-module assembly to the technical service or installer ready for
installation. It should be installed as follows:
1. Install the valve assembly by positioning the module so that marking 2 (APPENDIX 1 - Fig. 3) coincides
with the mark on the valve cover, carefully lower the module until it is correctly in place with respect to
the screw 3 (APPENDIX 1 - Fig. 4). In a situation where it does not fit, the screw may be rotated until it
couples with the motor pin (4) (APPENDIX 1 - Fig.4). Care must be taken not to lower it too brusquely since
this could damage the module's microswitches.
2. Install the three screws (11) (APPENDIX 1 - Fig. 3 ).
3. Remove the cover 1 (APPENDIX 1 - Fig. 2) by removing the four screws (13) in order to access the
connection strip.
4. Connection (MAKE SURE THERE IS NO MAINS VOLTAGE). Connect the cables as indicated in the attached
diagram. IMPORTANT! Use the gland seals that come installed in the module.
5. Replace the cover 1 (APPENDIX 1 - Fig. 2) and replace it with the screws (13).
6. Connect the power input to the control board. The valve will be in the Filtration position, remaining in
operating position when the programmed time comes into operation

5.3 TEMPORARY CONVERSION Of THE SYSTEM TO MANUAL OPERATION.

The module should be dismounted as described in Section 5.1.
Once the supply system is out, unplug the wires in the control box (L-N) that supply the electronic module.
Disconnect the wires from terminal (J10) on the electronic module and connect them to each other with
a bridge between these two terminals.
Remove screw (3) (APPENDIX 1 - Fig. 4), and pull the pawl (5) upwards, then (see APPENDIX 1 - Fig. 5)
remove the pin (6) in the direction of the arrow sale, remove part (7), leaving the valve in position for
installing the handle.