Drive Units
7-3. Setting the SCSI ID numbers, etc.
s Procedure for the setting the SCSI ID Nos. and other jumpers, please refer to the specified section(s) of the corresponding
drive instruction manuals.
s Make sure to turn the power OFF before starting with the setting procedure. If the procedure is carried out with the power
ON, it will cause malfunction.
s The new ID Nos. will become effective from the moment the power is turned on.
s The new SCSI ID Nos. should not conflict with the ID Nos. of other SCSI equipment on the same SCSI bus.
s The SCSI ID numbers should be in the range from 0 to 7. Numbers from 8 to 15 cannot be used.
7-4. Connecting the cables
s For the positions of the connectors for the cables from the optional drives, please
refer to the relevant instruction manuals for the drives.
1.
Connect the control cable (14P).
• Connect the control cable having the same number
as the drive bay number.
2.
Connect the power cable (14P).
(The figure shows the case of the MC-R434U.)
3.
Connect the two LVD power cables (6P) to the SE-LVD
conversion board.
• Both cables have identical connector types, so that
either cable can be connected to either connector on
the SE-LVD conversion board.
4.
Connect the internal SCSI (SE) cable (50P) to the SE-
LVD conversion board.
• The other end of the internal SCSI (SE) cable is con-
nected to the library SCSI board in the library.
5.
Connect the internal SCSI (LVD) cable (68P) to the
drives.
• The other end of the internal SCSI (LVD) cable is con-
nected to the SE-LVD conversion board.
Internal SCSI cable (approx. 1.0 m)
< Interior of library >
To SE-LVD conversion board
E22
Internal SCSI (LVD) cable
Terminator
Drive 4
Drive 3
Drive 2
4.
Drive 1
Terminator
Library SCSI board
Internal SCSI
5.
(SE) cable
1.
2.
68P
< Internal SCSI (LVD) cable >
Library
< SE-LVD conversion board >
Internal SCSI (SE) cable
50P
6P
3.
6P
68P
Internal SCSI (LVD) cable
To each drive
Control cable
14P
DIP switch
4P
Power cable
LVD
power cable