Télécharger Imprimer la page

HTW ADMIRA Manuel De L'utilisateur Et D'installation page 76

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 84
(B)
Indoor unit power wires
Outdoor unit
Indoor & Outdoor
connective wires
(purchased seperately)
(C)
Air switch
(purchased seperately)
Indoor unit power wires
Outdoor unit power wires
Outdoor unit
Indoor & Outdoor
connective wires
(purchased seperately)
(D)
(Only for the North American)
Air switch
(purchased seperately)
Outdoor unit power wires
Outdoor unit
Air switch
(purchased seperately)
NOTE: The cographs are for explanation
purpose only. Your machine may be
slightly di erent. The actual shape shall
prevail.
Page 34
Air switch
(purchased seperately)
Indoor unit
Air switch
(purchased seperately)
Indoor unit
Indoor & Outdoor
connective wires
(purchased seperately)
Indoor unit
76
Outdoor Unit Wiring
WARNING
Before performing any electrical or wiring
work, turn o the main power to the
system.
1. Prepare the cable for connection
a. You must rst choose the right cable
size. Be sure to use H07RN-F cables.
NOTE: In North America, choose the
cable type according to the local
electrical codes and regulations.
Minimum Cr oss-Sectional Ar ea of
Power and Signal Cables (For reference)
Rated Curr ent of
Nominal Cr oss-Sectional
Appliance (A)
> 3 and ≤ 6
> 6 and ≤ 10
> 10 and ≤ 16
> 16 and ≤ 25
> 25 and ≤ 32
> 32 and ≤ 40
CHOOSE THE RIGHT CABLE SIZE
The size of the power supply cable, signal
cable, fuse, and switch needed is determined
by the maximum current of the unit. The
maximum current is indicated on the nameplate
located on the side panel of the unit. Refer to
this nameplate to choose the right cable, fuse,
or switch.
NOTE: In North America, please choose the
right cable size according to the Minimum
Circuit Ampacity indicated on the nameplate
of the unit.
b. Using wire strippers, strip the rubber
jacketfrom both ends of the signal cable
to reveal approximately 15cm (5.9") of
wire.
Area (mm²)
0.75
1
1.5
2.5
4
6

Publicité

loading

Ce manuel est également adapté pour:

F-035admr32F-052admr32