English
VADOplex
Packing list
No.
Item
1
Controller incl. Power-Wire
2
Tubes green (3m)
3
User Manual
Pad
4
(depends on indication)
5
Box for controller
Safety packaging in foam for controller
6
VADOplex applied parts by intended use
No.
Item
1
Tubes green (3m)
2
Pad (depends on indication)
VADOplex accessories list
Depends on indication
Foot Pads
1 piece of Foot Pad, Size Medium (37-41), left
1 piece of Foot Pad, Size Medium (37-41), right
1 piece of Foot Pad, Size Large (42-47), left
1 piece of Foot Pad, Size Large (42-47), right
1 pair of Foot Pads, Size Medium (37-41)
1 pair of Foot Pads, Size Large (42-47)
1 box with 5 pairs VADOplex Foot Pads, Size Medium (37-41)
1 box with 5 pairs VADOplex Foot Pads, Size Large (42-47)
Calf Pads
1 pair of Calf Pads
1 package (10 pairs) of Calf Pads
Hand Pads
1 piece of Hand Pad, left
1 piece of Hand Pad, right
Undercast Pads
1 Foot Pad for VACOped/VACOped Diabetic
34
Quantity
Item Number
1 pcs.
VXSY-07-1
2 pcs.
VXSY-TUBE-01-1
1 pcs.
WM-TEVX-21-1-1
piece/
see VADOplex
pairs
accessories list
1 pcs.
PM-VXBO-01-1
1 pair
PM-VXRS-01-1
Quantity
Item Number
2 pcs.
VXSY-TUBE-01-1
piece/pairs see VADOplex accessories list
Single patient use only:
The pads are to be used for one patient only and may neither
be used for several patients nor refurbished
Item-Number
VXFP-01-1-M-LI
VXFP-01-1-M-RE
VXFP-01-1-L-LI
VXFP-01-1-L-RE
VXFP-02-1-M
VXFP-02-1-L
VXFP-05-1-M
VXFP-05-1-L
Item-Number
VXCD-06-2
VXCD-06-2
Item-Number
VXHP-04-1-LI
VXHP-04-1-RE
Item-Number
VXCP-03-1
Device description
Device description Front side
●
Display
D
●
Control panel
A
●
Power switch on/off
E
Device description Rear side
●
Right tube connector
B
●
Left tube connector
C
●
Transport handle and bed mounting
I
●
Ventilation slots
G
●
Information on error messages
H
●
Supply cable connection
J
●
Communication interface for technical personnel
Device initialisation
Insert the power cable plug into a socket.
●
Caution: Make sure that the power cable plug is easily accessible and that it can be
unplugged at any time.
Plug the connecting hoses into the corresponding outputs.
●
To switch on the device, press the power switch to I.
●
After the device is switched on, the power switch is lit up green. A welcome messages is
shown on the display.
6
A 5-second countdown follows (5-4-3-2-1-0), shown at the top left on the display.
(
, illustrated at 3 seconds)
7
The patient hours can be viewed in the line behind the little man:
The total operating hours of the VADOplex device are displayed underneath:
(
, Sample image with 0 patient hours and 626 total operating hours)
7
When is the device ready for operation? This screen indicates that the self-check is
●
complete and the device is ready for operation.
The first time the device is used, the following factory default settings are configured:
Program 1: 130 mmHg pressure with a pressure pulse duration of 1 second.
An overview for putting the device into operation is found at the front of the instructions
for use.
16
Control panel description
A
Start/Stop button
K
Individual pressure adjustment
-/
L
Mode button
M
F
1
2
4
.
8
8
35